Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Latest Product

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

Clover Incinerator update Social media site, including facebook,twitter,linkedin

we now publish mutil-social media for incinerator online marketing, this will be helpful our marketing and customer relationship.

 

http://www.facebook.com/hiclover

https://twitter.com/hiclovercom

https://www.linkedin.com/in/hiclover

https://plus.google.com/+IncineratorClover

https://www.youtube.com/c/IncineratorClover

https://www.pinterest.com/incinerators

http://cloverincinerator.blogspot.com/

http://cloverincinerator.tumblr.com/

http://vk.com/hiclover

https://www.instapaper.com/p/incinerator

https://www.flickr.com/photos/clover-incinerator/

 

 

 

Containerized Incinerators

Containerized waste incinerator is our latest design for market. This incinerator is build in ISO container before leave factory. After customer received container, install the chimney and connect with electric power and setup oil tank, that’s all. Now, the burning capacity can be 30 kgs/50kgs/100kgs per hour for ISO 20’feet container. This moveable/mobile incinerator can be move by truck to any site by local customer.

This kind of incinerator is good choice for different end-customer site, Service personnel can move to there and service at local site. It is also best service type for family pet cremation service and other emergency status.

How to Buy Clover Incinerators

1. Clover Medical save all rights to mend/update product information on website. The specifications are subject to change without prior notice.

2. We accept business term: FOB/C&F/CIF term, by sea/train, full container or bulk goods. 1. FOB (Free on Board), the price leave China port. 2. C&F (Cost and Freight), FOB price and freight cost. 3. CIF (Cost and Insurance and Freight), FOB price and insurance fee and freight cost.

3. Payment Term:
By sea: 50% deposit T/T (bank transfer) in advance, and 50% balance T/T before shipping day.
By Train: 100% T/T in advance.

4.Shipping Document & Packing: Generally, We supply (1)Bill of Lading (Way Bill), (2)Commercial Invoice, (3)Packing List ONLY.
If any further documents/certification and label print/words on packing material or documents which request by importer or local customs, whatever happen in China or oversea, should inform seller in advance and charge as actual cost. For example, Fumigation Certification, embassy certificate, BV/SGS…inspection, certificate of original (C/O), Form A, etc. Buyer must to inform seller in advance and pay these cost. Seller save all rights to postpone/cancel shipping and request lost cost cause this incident. If the importer local customs arrest/request penalty or other situation caused by buyer mistake, Clover Medical save all right to request compensation/litigation. Thanks for your cooperation.

5. The leading time is mostly 3-6 weeks, depending on the products and quantity.

7. Guarantee: One year for the equipment. We supply spare parts for maintenance, free charge within the first year and the delivery charge is on the buyer.

8. Insurance: Bear all risks of loss of or damage to the goods from the time they have passed the ship’s rail at the named port of shipment. we proposal apply All Risks insurance under each contract. When buyer pickup goods at local site, must inspect carefully. If any damage happened under insurance policy, buyer should inform insurance company and Clover Medical Limited immediately. We will provide necessary assistance.

Small Scale Medical Waste Incinerators

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm
incinarator (syc-10 oil),

Waste Incinerators International Market Analytics

Key Word:

small incinerators

medical waste incinerator

pet animal cremation incinerator

incinerator manufacturers

 

 

Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below:

 

Treatment capacity: small scale incinerator, large scale incinerator and incineration pant.

Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators

Incinerator fuel: gas incinerator, oil incinerator

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator

Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer.

Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA) , Haat (India)

Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

 

Pyrolytic incineration technical is traditional waste treatment way for many years. All over the world, in many countries, people anti incinerator because the incinerator will produce a large Dioxin in the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics.  Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from past commercial burning of waste.  Dioxins break down very slowly and past releases of dioxins from both man-made and natural sources still exist in the environment. Anyhow, we have to remind that, this is large scale incineration pant, generally more than 30 ton per day. This is a social problem, to analyze and suggest ways in different angles from the public, government, economic development, environmental protection, technology development, etc.

 

So, why we still use incinerator?

First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution control.

Second, for human body, pet animal, in many countries and regions, we desire to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of life.

 

As above two reason but not only above, we still use incinerators.

 

How you can find reasonable incinerator for your local site?

Incinerator is not a cheap equipment, generally the small scale model’s price around $5,000usd per unit and large scale model’s price more than $50,000usd per unit. So, before purchase one unit incinerator, you have to make clear following items:

A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you want to treatment?

B, small or large? This according to the waste output every day or the waste volume per feed time, like animal size.

C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some local site don’t have gas supply system.

And other technology items, like power(220v, 380v), waste feed door type, incinerator structure, etc.

 

After you clarify these, you can go to find a local or international manufacturers, asking prices, technical specifications and ultimately purchasing the right products.

Clover's Social Media