Spare Parts for Waste Incinerators and Burners

Aeration gate valve,Burner fuel pump,Circuit board (LM44.255C2BT),
controller for Riello FS10 gas burner,Emergency push button,


Fire proof flange gasket,Flexible Conduit,Fuel filter,Ignition transformer,
Incinerator Automatic Protection Operator(APO) Controller,
Nut for Temperature Thermocouple-Temperature  Probe,PLC auto control incinerator,
Solenoid,Stainless steel tension wire,Temperature display controller K type,
Temperature display controller S type

MEDICAL WASTE INCINERATOR WITH CAPACITY 500Kg/h

*Primary combustion chamber *Secondary combustion chamber *Smoke filter chamber * Stainless Steel chimney

*Auto PLC control system *Italy brand burner * Automatic Protection Operator(APO) *Heavy duty refractory chamber

*Corundum Temperature Thermometer *CE/ISO certification,etc

 

 

Incinerator Items/Model

HICLOVER TS500(PLC)

 

Burn Rate (Average)

500-600 kg/hour

Feed Capacity(Average)

600kg/feeding

Control Mode

PLC Automatic

Primary Combustion Chamber

3000Liters(3.0m3)

Internal Dimensions

2100x1200x1200mm

Secondary Chamber

1500Liters(1.5m3)

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

380V 3P

Power

4.8Kw

Burner Type

Italy Brand

Oil Consumption (kg/hour)

44

 

Fuel Type Item
Oil Type Oil Burner
Oil Tank(200Liters)
Blower
photo cell
mixed chamber material
Incinerator PLC Control Case
Ceramic Fiber Rope
temperature controllers
Temperature Thermocouple
 
 

ITEM DESCRIPTION

SPECIFICATIONS

1. Site clearance and preparation (remove all old items)

2.      Concrete foundation with iron bars, as incinerator base (30 cm high, above the ground)

UP TO 5.0 M² and 30 cm high

3.      Cast fire resistance concrete foundation with iron bars to support the chambers operating at high temperatures

10 cm high casted on site

4.      Burner complete unit, imported, connected with diesel pipes, filters and valves, mounted and tested

Up to 20 L/h, diesel

5.      Complete set of multi-unit control panel, constructed and installed, with temperature controllers connected to thermocouples, electrical wires to different units connected to the chambers, switches and power supply for blowers and burners.

Control panel (1 m x 1m), switches, lights and power supply

6.      Blower with complete housing (air supply system, with galvanized steel piping electric cable and plug). Supply also blower support stand fixed on the wall or on the concrete foundation.

1.1-2.0 kW Three phase ,380-415v x50Hz

7.      Complete set of thermocouples and controllers with optimal sensitive temperature range between 800 and 1200 degree Celsius, with signal carrier wires. Cut and drill the chamber tops to allow insertion of thermocouples, without leading to smoke leakage

800-1200 deg C

8a.     Complete cover for the top of secondary and primary chambers to prevent collapse of the chamber insulation.

Primary chamber round top

 

Secondary chamber tops

 

Retention chamber cover top (120-180 cm diameter)

8b. Top cover grates for ash collection chamber to allow for ash collection.

 

9a.      Provide the primary chamber feeding door frame with Angle iron, plate, insulation and by castable heat resistant surface (heavy duty door hinges, door frame grooves)

Complete door with accessories (80 cm x 80 cm)

9b.      Provide offloading door for the ash collection chamber with heavy duty angle iron, plate, insulation and by castable heat resistant surface (heavy duty door and grooves) manual loading and offloading doors.

 

Complete door with accessories (80 cm x 80 cm)

10.   Supply grate in complete set with four units, above combustion chamber floor for ash deposition and air circulation, cast the blower duct opening to remain open throughout.

18 mm round bars provide set of 80 cm x long x 80 cm wide

11.   Secondary chamber door and cover plate, with bolts & nuts size M16 to allowing for periodic cleaning to remove fly ash

M16 with 10-mm thick plate

12.   Fix firebricks for primary chamber, secondary chambers, retention chamber and connections, hold with iron frame, with bolts and nuts, welded on angle iron and flat bars

7.5 cm x 11.5 x 23 cm b ricks x 6 mm angle iron x 6 mm flat bars

13.   Steam pipe exhaust, with side supports and base on the ground, surrounded with hot water generation system

6 m to 10m tall with supports

14.   Firebrick made or casted pipe connector from secondary chamber to retention chamber with insulation and cover plates/show

Minimum 8-inch duct any section x 2 m

15.   Firebrick made pipe connector from primary chamber to secondary chamber with insulation and cover plates/show

Minimum 8-inch duct at any section x 1.5 m

16.   Outside wall (10 mm) reinforced on the concrete covering all parts of primary with necessary opening and connections.

 

Up to 15-20m²

17a.   Outside wall (10 mm) reinforced on the concrete covering all parts of secondary chambers.

 

Up to 4m²

17b. Outside wall (10 mm) reinforced on the concrete covering all parts of retention chambers

Up to 7.0 m²

18.   Allow for burner pipe with inside end trimmed to firebricks and outside connected to burner flange (cut from complete pipe)

5 inches diameter

19.   Electricity connections to all parts, single/three phases, with cable covered

Standard (single phase three phase)

20.   Insert show-plate (SS) and insulation to cover the chimney connector from retention chamber operating at high temperature.

4mm plate SS with 1.5-inch x 6 mm angle iron

21.   Insert show-plate (SS) and insulation to cover the chimney connector from cyclone operating at high temperature.

4mm SS plate with 1.5-inch x 6 mm angle iron

22.   Supply complete fuel tank with supports and diesel connections to the burners 200 liters tanks with ½ inch pipe connections and accessories (filter, valves, unions, elbows, etc.)

Standard

23. Waste loading/Feeding stand above ash collection chamber

7.0 m² area arranged around the primary chamber, 90cm high.

 

24.   minor repairs: shade for incinerator

Roof, wall and surroundings

25. Warrant period

At least two years warrant period for mechanical parts

26. spare parts

Available spare parts for the machine

27. Manual book

Manual in English to be provided

28.Training of Operators

All responsible staff on working days.

 

 

29. supply a complete maintenance kit with accessories (photo cell, temperature controllers, spanners) provide related drawings (process flow chart, civil, mechanical and electrical drawings)

 

 

 

 

 

 

Hospital Syringe and Destroyer-Needle Destroyer-Needle Incinerators

1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ).
2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk.
3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization immediately. Destroy syringes, infusion set, can not use again.
Medical Needle Incinerator: Melt the needle waste, cut off syring tube with needle, cut off the infusion tube.
Model SYC19, Price: $110usd/set, MOQ: 5 sets.
EXW factory term(donot including shipping cost)
Purchase email:  info@hiclover.com
Qustion1: If request 1-4 set only, how to do?
Answer: We will plus $50-$200usd fee per order.
Qustion2: If request more than 5 sets only, any discount?
Answer: We will  supply discount quotation accordingly.

Incinerator Items/Model HICLOVER TS5(PLC) HICLOVER TS10(PLC) HICLOVER TS20(PLC) HICLOVER TS30(PLC)
Burn Rate (Average) 5-10 kg/hour 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour
Feed Capacity(Average) 10kg/feeding 20kg/feeding 40kg/feeding 60kg/feeding
Control Mode PLC Automatic PLC Automatic PLC Automatic PLC Automatic
Combustion Chamber 52L 100L 210L 330L
Internal Dimensions 50x35x30cm 50x50x40cm 65x65x50cm 75x75x60cm
Secondary Chamber 26L 50L 110L 180L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 2P 220V 2P 220V 2P 220V 2P
Power 0.5Kw 0.5Kw 0.5Kw 0.5Kw
Burner Type Italy Brand Italy Brand Italy Brand Italy Brand
Oil Consumption (kg/hour) 4 6 8 12
Gas Consumption (m3/hour) 6.2-11.4 6.2-11.4 8-15.7 9.8–20
Temperature Monitor Yes Yes Yes Yes
Temperature Thermometer Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube
Temperature Protection Yes Yes Yes Yes
Automatic Cooling Yes Yes Yes Yes
Automatic False Alarm  Yes Yes Yes Yes
System Testing Model Yes Yes Yes Yes
Time Setting Yes Yes Yes Yes
Progress Display Bar LCD Display LCD Display LCD Display LCD Display
Oil Tank 200L 200L 200L 200L
Oil Tank Stand 190cm Height 190cm Height 190cm Height 190cm Height
Liquid level Display  Yes Yes Yes Yes
Feeding Door 20x20cm 30x30cm 45x40cm 55x50cm
Chimney 2Meter 3Meter 3Meter 5Meter
Chimney Type Stainless Steel 304  Stainless Steel 304  Stainless Steel 304  Stainless Steel 304 
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1000kg 1500kg 2200kg 3000kg
External Dimensions 120x80x110cm 140x90x120cm 160x110x130cm 175x120x140cm

guidelines on waste management Incinerator Model YD-20C

Item

Specification

Model

YD-20C

Main Product List

 

Primary Combustion Chamber

Secondary Combustion Chamber

Mix-Combustion Chamber

Smoke Filter Chamber

Incinerator Control Case

Chimney:5.0Meters *(upgrade to Stainless Steel, free cost)

Italy oil burner: 02 sets

Oil Tank: 100Liters

 

Optional:

Mobile Trailer for Incinerator


Mobile Type Incinerator


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration

Items/Model

YD-20C

Burning Rate (kgs/Hour)

Average 20 kgs/hour

Feed Capacity (kgs)

Average 40 kgs/feeding

Equipment Weight

2100 kgs

Primary Chamber (Liters)

200

Secondary Chamber (Liters)

140

External Dimensions (cm)

170x140x160

Internal Dimensions (cm)

55x55x65

Oil Tank(Liters)

100

Door Opening (cm)

38 x 48

Chimney (M)

5.0

Chimney Type

Stainless Steel

Secondary Chamber

YES

Mix-Combustion Chamber

YES

Smoke Filter Chamber

YES

Combustion Fuel

Oil/Gas

Residency Time

2.0 Sec.

Temperature Monitoring

YES

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2021-02-23

HICLOVER Top Feeding Door Waste Incinerators

HICLOVER Top Feeding Door Waste Incinerators

***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber
***Optional Wet Scrubber System(1 section or  3 sections)

▲Large Feeding Door
▲Better for Animal Waste Cremation
▲HICLOVER Brand Section


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items Side Loading Door Top Loading Door
Cost Cheap High cost
Manufacture Tech. Easy A litter difficult
Safty safe safer
Incinerator Shape L/ I
Loading manual big door can be by Forklift
Land occupation small big
Ash door same with feeding door or alone alone
market share Most-CHINA/USA/INDIA Few- UK/USA
Dooring open type Manual Pry bar/Hydraulic pressure
Dooring Open size small big
Better for medical bag waste animal waste
open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke





HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-08-07

Municipal solid waste incineration equipment

Municipal solid waste incineration equipment

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw
Diesel Oil Consumption (kg/hour) 8.4 10.9 13.3 16.9
Natural Gas Consumption (m3n/hour) 10.1 13 16 20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm
Chimney 3Meter 3Meter 5Meter 5Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm

The system to be also incorporated with sludge oil Burner, diesel oil burner, control panel and instrumentation, 
exhaust gas fan, exhaust gas regulating damper including a servo monitor.
Minimum diesel oil service tank capacity -500L
GPL propane incinerator for treatment of pharmaceutical and hospital waste with wet or dry gas emissions filter
The silt is 300 kg / hr
Mobile crematorium for human
Portable Drum Incinerators
Burning rate: 8-15 kg/hr (depending on material to be incinerated)
Maximum load capacity: 25 kg approx.
50-100 Kg/Hr Capacity containerized Incinerator for the medical waste incineration.
mounted and installed in the container 
is price inclusive of the container price ?
is there an electrical power cabinet ? 
Buner: what is control system -PLC ?
flue gas at  chimney outlet  : do you have any filters after secondary combustion chambers 
what are controllers eg temperature probes 
* minimum 50Kg/hour Incinerating capacity 

HICLOVER – Medical Environmental, WWW.HICLOVER.COM, Waste Incinerators, 
Medical Waste Incinerator,Pet Animal Cremation, Solid Waste Incinerators

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator(Containerized Mobile Incinerator)

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  
Nanjing Clover Medical Technology Co.,Ltd.



 

2020-07-07

400mm and 1600mm Melt blown Production Line and ES Fiber Production Line and N95 Mask Machine and Disposable Mask Machine

1. N95 and Disposable Mask Machine

 

2. 400mm and 1600mm Melt blown Production Line

3. ES Fiber Production Line

 

 

 

N95 Face Mask Machine Production Line

Melt blown Production Line

 

A.)Optional Capacity: 1600mm

Efficiency: 95-97%

FOB Term Price: USD per set

Price Valid: 5days.

Ave.60 Days ready for shipping.

In stock Price: USD per set

 

 

B.)Optional Capacity: 400mm

Efficiency: 40-50% .

FOB Term Price: USD per set

Price Valid: 5days.

Ave.20 Days ready for shipping.

Payment: TT 70% In advance, TT 30% before leave factory

Shipping: 1*20′ container per set, Ave. 2000Kgs.

 

Main Parts: Extruder, mold, winder, oven, ultrasonic

Daily Capacity100-150Kgs/24Hours

Screw extruder100-150Kgs

Motor power: 15KW frequency conversion speed regulation
Reducer speed ratio: 1:10 or 1:16
Screw length to diameter ratio: 30: 1
Screw diameter: 50mm
Winding machine diameter:
630mm
Winding machine drive motor power: 0.55kw
Speed ratio of winder drive reducer (if any): 1:71
Air heater power: 15kw
Power of vacuum calciner: 12kw
The size of vacuum calciner: 500 × 300 × 200
Ultrasonic power: 1800, frequency 28kHZ
Ultrasonic sink size: 800 × 300 × 250

 

 



HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-20

N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set

N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set

N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set

Dimension(L*W*H): 1037*855*1780

Power Supply 15.3kw mono phase

Net Weight: approx.: 1500kg

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-10