Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Biomedical Incinerator
Product Description
YDC incinerator is latest layout for waste treatment, laboratory incinerator, big incinerator factory uk, big scale incinerator, big scale incinerator health care waste, low capacity incinerators, low cost incinerator maker, include health care waste, animal cremation and other solid waste. This equipment quality structural for types of website, such as hospital, environmental department, animal cremation services, etc… CLOVER Incinerator supply updated models with dual combustion chamber, mix combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.
Items | Specification | |||
YDC Model | YD-10C / YD-20C / YD-30C / YD-50C | |||
Main Product List | Primary Combustion Chamber | |||
Secondary Combustion Chamber | ||||
Mix Combustion Chamber | ||||
Smoke Filter Chamber | ||||
Incinerator Common Control Case | ||||
Stainless Steel Chimney | ||||
Italy oil/gas burner: 02 units | ||||
Oil Tank (if oil fuel) |
Burning and Incineration Methods
open burning on the floor results in the incomplete combustion of waste and the discharge of various
Means of decreasing the
quantity of waste that has to finally be disposed . Generally,
Figure 1 — Open Burning on the Ground
Burn Boxes
There are two standard kinds of burn boxes. The enclosed burn box is constructed using heavy sheets of steel or other metal while the open burn box has been constructed using expanded metal grating. The latter type is commonly referred to as a burn cage. These devices are not commercially-available in Nunavut, but can be constructed using locally available materials. For example, the enclosed metal burn box shown in Figure 2 is created from a dump truck bed and steel plating. Combustion air is provided passively using a pure draft making electricity unnecessary. Burn boxes are only chambered units. Waste is elevated off the bottom of the box by placing it on grates within the unit. Unburned bottom ash falls through the grate through burning making removal easier once a sufficient amount has collected. Combustion air in enclosed burn boxes is typically provided by cutting holes near the base of the box allowing for better mixing with all the burning waste.
Open burn boxes, or burn off cages, are still an improvement over enclosed burn boxes as the waste is subjected to natural drafts through the metal grating on all surfaces such as the bottom. This permits air to better mix with burning waste and promotes more efficient combustion during the burning period.
Evenly spaced vents or holes cut above the base of the barrel supply combustion air. These features provide for increased passive under-fire ventilation and encourage better contact between the waste being burned and incoming atmosphere. The basket insert is topped with a hinged lid and a chimney port for attachment of an exhaust pipe or stack. The lid helps to increase heat retention and holding time within the barrel while also allowing for easier mixing and loading of the waste. The removable mesh basket enables access to this unburned bottom ash.
Modified burn barrels could be built using commonly available materials. They could either be pre-built independently or hauled to the site for meeting. Detailed construction programs are given in Appendix 2.
Although modified burn barrels are intended to create an edge over open burning on the floor, burn boxes and unmodified burn barrels through reaching higher burn temperatures and enhanced turbulence and holding time, stopping combustion of waste and the discharge of pollutants to the atmosphere continue to be possible. In fact, emissions testing by Environment Canada on a modified burn in April 2011 imply that these devices don’t provide any improvement over open burning on the floor concerning
Figure 4 — Modified Burn Barrel
emissions caliber, particularly if wet food waste is added to the waste mix. Other common problems include easily overfilling the unit and loading waste which should not be burned (refer to section 3.2). Wet or frozen masses of waste are particularly difficult to burn along with the consequent partly burned food waste could still attract critters. The proper operation of modified burn barrels is essential to achieving the most efficient burn possible. Basic operating instructions are offered in section 4.1.
Burn barrels are capable of burning only tiny quantities of waste. Like burn boxes, they reduce the danger of fire spreading to plant and tundra by comprising the burning waste to a certain site.
The unmodified burn barrel is generally a 45 gallon, or 205 litre, metal fuel or oil drum with the top removed. These devices typically operate in a very low temperature resulting in incomplete combustion of the waste and production of large quantities of smoke and fly ash.
A modified burn is a 45 gallon metal fuel or oil drum that’s been affixed with apparatus or features which lead to greater burn temperatures, better mixing of the atmosphere and a longer holding time.
The burning and incineration procedure used is a major element in determining what type of waste could be safely and efficiently disposed of. The methods widely used in Nunavut contain open burning on the floor, unmodified burn barrels and assorted mechanical incineration systems. Other helpful methods include using burn boxes and modified burn barrels. Each procedure is discussed individually in the subsequent sections.
2.1.1 Open Burning
Open burning means that the burning of waste in which limited or no control over the combustion process can be exercised from the operator. This method includes burning solid waste directly on the open floor or in burn boxes or burn barrels and often does not achieve the temperatures or holding time required for complete combustion of the waste to happen. This results in the creation of potentially hazardous pollutants and ash, which are likely to affect nearby water and land. Food waste that is not entirely burnt through open burning can also be a powerful attractant for creatures.
The many open burning methods can also present a danger of uncontrolled plant and tundra fires through the discharge of hot sparks or embers. The level of fire hazard depends on the sort of open burning used, its place, the skill of the operator and the environmental conditions which exist in the time (i.e. dryness of the surrounding vegetation, wind).
The open burning of solid waste remains a common practice in Nunavut. It’s the policy of this Department of Environment to remove or decrease open burning of mixed solid waste to the extent practicable and to promote more acceptable methods of disposal and incineration.
Open Burning on the Ground
Open burning the floor involves burning solid waste that’s been piled directly on the surface of the floor or placed in a tiny open pit. Many large and small communities and camp operators in Nunavut continue to practice open burning on the floor as a
Assembled with hinged tops to enable easier loading and cleaning.
Unlike open burning on the floor, burn boxes help to contain the burning waste within a specific place reducing the possibility of fire spreading to other disposal areas or surrounding tundra, while enabling moderate levels of waste to be burned.
Burn Barrels
There are two standard kinds of burn barrels — that the unmodified burn barrel and modified burn barrel.
Figure 3 — Open Metal Burn Box
emissions quality, particularly if wet food waste is added to the waste mixture. Other common problems include easily overfilling the unit and loading waste that should not be burned (refer to section 3.2). Wet or frozen masses of waste are particularly difficult to burn and the resulting partly burned food waste may still attract animals. The proper operation of modified burn barrels is critical to achieving the most efficient burn possible. Basic operating instructions are provided in section 4.1.
Burn barrels are capable of burning only small volumes of solid waste. Like burn boxes, they reduce the risk of fire spreading to vegetation and tundra by containing the burning waste to a specific location.
Crematorium for Small Animals Gear
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste may use within this equipment? A: This equipment to medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid gas and waste waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Remedy capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour)doesn’t mean any waste material. The animal/pet combustion speed around 2/3 of average capacity.
Clover incinerator use time per day up to 24 hours. Between every feed/combustion time, there are approximately 0.5-1 hours cooling time and time to get feeding waste. Actual combustion time daily is about 16 hours. The lifetime of incinerator involving 5-10 year based on use.
Ordinarily, we proposition little laboratory, little clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people every day. If there are 200 sickbed in the clinic, that's mean you need 1 incinerator capacity around 400kgs every day, switch to capacity per hour is approximately 30-40 kgs per hour. According the operation time every day, waste material, funding, development, etc, you may use capacity from 30-50 kgs each hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Meeting and Testing A: We provide all documents and incinerators simple to installation and operation. Small scale clinical incinerator, smart ash incinerator, 30 kg per hour-incinerator, animal incinerator for sale, incinerators, incinerators for sale, Client can send people visit our factory to find out operation and installation. Generally, We do not send engineer to local website if not request. The dispatch cost is extra based on order. The second combustion chamber: 1000-1200 centi level. PLC mode based on model and order.
Q: Operation and maintenance costs A: Operation cost based on fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000USD annually maintenance according version, use situation.
One individual can service 02 unit incinerators. The staff should have fundamental electrician understanding to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and understand risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items | Specification | ||||
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Model | TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) | ||||
Main Product List | Double Combustion Chamber | ||||
Smoke Filter Chamber | |||||
PLC Mode Control Case | |||||
Stainless Steel Chimney | |||||
Italy oil/gas burner: 02 units | |||||
Oil Tank (if oil fuel) |
Incinerator: Calculations for Bunker Capacity
Basic Info.
Product Description
Key Features: * All versions with Dual combustion room. * Stainless Steel chimney/stack, long life. *based on sequence * High fever, long life of incinerator. * Free or minimal installation on site. * High burn rate, from 10kgs to 500kgs per hourto 6ton per day. * PLC Control Plane. *based on order * New Design for pet animal cremation business. * One year warranty on incinerator and parts in stock.
Application Scope: 1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. 3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation
Nanjing Clover Medical Technology Co., Ltd.. Is a leading waste incinerator maker in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is primary waste treatment all the planet, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr. Up to 6ton per day. Currently, we provide where incinerate pet in bangkok, where to buy medical incinerator in china, that zambia incinerator, why clinkers formed in incinerator performance, xiamen city east incineration, distinct series for local client requirements and layout upgraded incinerator with our leading technology. The upgraded design feature of our assortment of incinerators make them one of the most cost effective in the world.
Items/Model | YD-200 | YD-300 | YD-500 | YD-600 |
Burning Rate (kgs/Hour) | 200 kgs/Hr. | 300 kgs/Hr. | 500 kgs/Hr. | 600 kgs/Hr. |
Feed Capacity (kgs) | 400 kgs | 500 kgs | 800 kgs | 1100 kgs |
Equipment Weight | 7600 kgs | 8300 kgs | 13000 kgs | 16500 kgs |
Primary Chamber (Liters) | 2000 | 2400 | 4000 | 5500 |
Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 |
External Dimensions (cm) | 270 x 185 x 380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 |
Internal Dimensions (cm) | 180 x 115 x 96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 |
Oil Tank(Liters) | 300 | 500 | 500 | 500 |
Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 |
Chimney (M) | 10 | 10 | 14 | 14 |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Secondary Chamber | YES | YES | YES | YES |
Mix-Combustion Chamber | YES | YES | YES | YES |
Smoke Filter Chamber | YES | YES | YES | YES |
Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Temperature Monitoring | YES | YES | YES | YES |
Hospital Waste Incinerator 200 Kgs Per Hour Capacity
Product Description
Clover provide medical waste incinerators, animal and pet cremators, other solid waste incinerators to over 30 countries. We’ve re-designed the incinerators lining configuration. We have also installed and designed our very own PLC computer system into incinerator capacity of burner for medical incinerator, catalogue of incenarator for pharmaceuticals waste, chesp incinerator, china hazardous waste, operation system. Clover understand it’s essential that build them better, keep it simple and offer a fantastic support. We create quality products which provide excellent revenge on investment, so our incinerators are the most powerful and thermally efficient in the business. The incinerator lines have little scale to large scale, up to 500kgs per hour. The combustion chamber use high strength material, expensive cost but far better quality than competitors. Incinerator operation system use PLC program control mode, give the complicated manual operation. This equipment quality structural for kinds of site, like hospital, environmental division, animal cremation services, etc… CLOVER Incinerator provide updated versions with double combustion chamber, mix combustion chamber and smoke chamber using refractory lines, along with the combustion chamber temperature up to 1200 deg C.
Items/Model | YD-200 | YD-300 | YD-500 | YD-600 |
Burning Rate (kgs/Hour) | 200 kgs/Hr. | 300 kgs/Hr. | 500 kgs/Hr. | 600 kgs/Hr. |
Feed Capacity (kgs) | 400 kgs | 500 kgs | 800 kgs | 1100 kgs |
Equipment Weight | 7600 kgs | 8300 kgs | 13000 kgs | 16500 kgs |
Primary Chamber (Liters) | 2000 | 2400 | 4000 | 5500 |
Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 |
External Dimensions (cm) | 270 x 185 x 380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 |
Internal Dimensions (cm) | 180 x 115 x 96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 |
Oil Tank(Liters) | 300 | 500 | 500 | 500 |
Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 |
Chimney (M) | 10 | 10 | 14 | 14 |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Secondary Chamber | YES | YES | YES | YES |
Mix-Combustion Chamber | YES | YES | YES | YES |
Smoke Filter Chamber | YES | YES | YES | YES |
Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Temperature Monitoring | YES | YES | YES | YES |