Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Little Incinerator Yd-50c
Product Description
Nanjing Clover Medical Technology Co., Ltd..
Items/Model | YD-10C | YD-20C | YD-30C | YD-50C |
Burning Rate (kgs/Hour) | 10 kgs/Hr. | 20 kgs/Hr. | 30 kgs/Hr. | 50 kgs/Hr. |
Feed Capacity (kgs) | 40 kgs | 40 kgs | 50 kgs | 80 kgs |
Equipment Weight | 1200 kgs | 1200 kgs | 1800 kgs | 2200 kgs |
Primary Chamber (Liters) | 200 | 200 | 250 | 400 |
Secondary Chamber (Liters) | 140 | 140 | 140 | 140 |
External Dimensions (cm) | 170x140x160 | 170x140x160 | 170x140x190 | 180x160x200 |
Internal Dimensions (cm) | 55x55x65 | 55x55x65 | 55x55x85 | 70x70x85 |
Oil Tank(Liters) | 50 | 100 | 100 | 150 |
Door Opening (cm) | 38 x 48 | 38 x 48 | 38 x 48 | 45×55 |
Chimney (M) | 5 | 5 | 5 | 5 |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Secondary Chamber | YES | YES | YES | YES |
Mix-Combustion Chamber | YES | YES | YES | YES |
Smoke Filter Chamber | YES | YES | YES | YES |
Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Temperature Monitoring | YES | YES | YES | YES |
1st. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
2nd. Chamber Temperature | 1000degree-1200degree | 1000degree-1200degree | 1000degree-1200degree | 1000degree-1200degree |
YDC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment caliber structural for kinds of site, such as hospital, incinerator for animals purchase price, incinerator for burning waste, incinerator for cremation china, incinerator for laboratories, incinerator for lab animals, ecological division, animal cremation bureaus, etc.. CLOVER Incinerator supply updated models with double combustion chamber, mix combustion chamber and smoke filter chamber using refractory lines, and the combustion chamber temperature up to 1200 deg C.
Technical Prerequisites for Medical Waste Incinerator
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste may use in this gear? A: This gear to medical waste, pet animal, Municipal waste, reside waste. Prohibit any volatile and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Remedy capacity A: Average Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour)doesn’t indicate any waste material. The animal/pet combustion rate around 2/3 of average capacity.
Clover incinerator use time daily to 24 hours. Between every feed/combustion time, there are approximately 0.5-1 hours cooling time plus time to get feeding waste. Actual combustion time per day is around 16 hours. The life of incinerator involving 5-10 year based on use.
Generally, we proposal little laboratory, little clinic use capability under 20 kgs per hour. When incinerator use in hospital, then please compute the waste output around 2kgs per people each day. If there are 200 sickbed in the hospital, that's imply you need 1 incinerator capability around 400kgs per day, change to capacity per hour is approximately 30-40 kgs per hour. According the operation time per day, waste material, budget, growth, etc, you may use capacity from 30-50 kgs each hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing A: We supply all files and incinerators easy to installation and functionality. Customer can send people visit our factory to find out installation and operation. Generally, We do not send engineer to local site if not request. The dispatch price is additional based on order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi degree. The next combustion chamber: 1000-1200 centi degree. PLC mode based on model and order.
One person can service 02 device incinerators. The team should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, animal crematorium gear, animal crematory bidding, animal incinerater, animal waste incinerators, cattle incinerator, economical incinerator, china incinerator exporter, and know risk of medical waste to safeguard employee self with essential protection element.
Q: The Residency period in combustion chamber A: 02 sec.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, animal crematorium equipment, animal crematory bid, animal incinerater, animal waste incinerators, cattle incinerator, cheap incinerator, china incinerator exporter, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Model Poultry Incinerator
Basic Info.
Product Description
Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long lifetime. *based on order * High fever, long lifetime of incinerator. * Free or minimal installation onsite. * High speed, from 10kgs to 500kgs per hourto 6ton per day. *based on order * New Design for pet animal cremation business. * One year guarantee on incinerator and parts in stock.
Application Scope: 1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. 3. Community & Sea Port & Station: Municipal Solid Waste, etc. 4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation
Incinerator is a incineration equipment, direct fire squander by gasoline fuel or oi fuel. As different circumscription, incinerator could be named many words as under:
Therapy ability: Small scale incinerator, large scale incinerator and incineration pant.
Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators
Incinerator fuel: Gas incinerator, oil incinerator
Waste to Energy (WTE): WTE incinerator, non-WTE incinerator
Incinerator Manufacturer: China incinerator producer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer.
Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)
Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
Items/Model | YD-200 | YD-300 | YD-500 | YD-600 |
Burning Rate (kgs/Hour) | 200 kgs/Hr. | 300 kgs/Hr. | 500 kgs/Hr. | 600 kgs/Hr. |
Feed Capacity (kgs) | 400 kgs | 500 kgs | 800 kgs | 1100 kgs |
Equipment Weight | 7600 kgs | 8300 kgs | 13000 kgs | 16500 kgs |
Primary Chamber (Liters) | 2000 | 2400 | 4000 | 5500 |
Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 |
External Dimensions (cm) | 270 x 185 x 380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 |
Internal Dimensions (cm) | 180 x 115 x 96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 |
Oil Tank(Liters) | 300 | 500 | 500 | 500 |
Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 |
Chimney (M) | 10 | 10 | 14 | 14 |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Secondary Chamber | YES | YES | YES | YES |
Mix-Combustion Chamber | YES | YES | YES | YES |
Smoke Filter Chamber | YES | YES | YES | YES |
Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Temperature Monitoring | YES | YES | YES | YES |
2 Chamber Medical Waste Incinerator
Product Description
YDC incinerator is newest layout for waste treatment, include health care waste, animal cremation and other solid waste. This equipment quality structural for kinds of website, such as hospital, environmental division, animal cremation services, etc… Animals waste medical waste china, aravali incinerator of 30 kg per hour capability price, bahrain, pet incinerator, batch incinerator in china, batch load crematory,
CLOVER Incinerator supply updated models with double combustion room, mix combustion space and smoke filter room using refractory lines, along with the combustion room temperature up to 1200 deg C.
Items | Specification | |||
YDC Model | YD-10C / YD-20C / YD-30C / YD-50C | |||
Main Product List | Primary Combustion Chamber | |||
Secondary Combustion Chamber | ||||
Mix Combustion Chamber | ||||
Smoke Filter Chamber | ||||
Incinerator Common Control Case | ||||
Stainless Steel Chimney | ||||
Italy oil/gas burner: 02 units | ||||
Oil Tank (if oil fuel) |