Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

20 Kgs Capacity Medical Incinerator


Product Description

Key Attributes:  * All models with Dual combustion room.  *based on sequence * High fever, long lifetime of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton daily.  * PLC Control Plane. *based on order  * New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and parts in stock. 

Nanjing Clover Medical Technology Co., Ltd.. Is a top waste incinerator maker in China. We’re local producer and among the greatest exporter of China. Pyrolytic incinerator gear technical is primary waste treatment all the world, for Medical Waste, Animal Incineration, home waste incinerator in china, hospital burner manufacturere, hospital diesel fuel fired incinerators, hospital gear burner 100kg daily, hospital incinerater, Pet cremation and other Solid wste. The potential from 10kgs/Hr. To 500kgs/Hr. Up to 6ton daily. Presentlywe supply different show for local client requirements and design updated incinerator with our top technology. The updated design characteristic of our range of incinerators make them among the most cost effective on the planet.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Incinerator in Hospital


Basic Info.

Model NO.:incinerator for medicial waste
Export Markets:Global

Product Description

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Picture  
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Medical Waste Incinerators


Basic Info.

Model NO.:medical waste incinerator manufacturers
Export Markets:Global

Product Description

Key Attributes:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long life. *based on order  * High temperature, long life of incinerator.  * Free or minimum installation on site.  * High speed, from 10kgs to 500kgs per hourto 6ton daily.  * PLC Control Plane. *based on order  * New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and components in stock. 

Application Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Is a top waste incinerator manufacturer in China. We are local manufacturer and among the largest exporter of China. Pyrolytic incinerator gear technical is main waste treatment all the world, such as Medical Waste, Animal Incineration, combustion chambers incinerator, business sale equipments of medical waste, concrete combustion chamber, concrete incinerator, containerized incinerator, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr. , up to 6ton daily. Currently we provide different series for local customer requirements and layout upgraded incinerator with our top technology. The updated design characteristic of our assortment of incinerators create them among the most cost effective in the world.

Items Specification
YD Model YD-30 / YD-50 / YD-100 / YD-150 / YD-200 / YD-300 / YD-500 / YD-600
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Hiclover Incinerator


Product Description

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
           
           
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

incinerators spacification


  • Installing a readymade concrete base (Precast) with Height 30 cm above the ground and 20 cm below the surface of the earth.
  • The dimensions of the base are increased by (2 meters) from the edge of incinerators
  • The rest of the accessories in all the trends even allows the worker directly feeding and maintenance work, cleaning and move easily taking into account the tendencies of the base toward the door for drainage of water.
  • The floor coating must be high-quality epoxy paint.
  • Install anti-rust and heat Umbrella of brick and steel (pyramid shape) of (5) meters height above the ground which installed with the edge of the concrete base by thick galvanized columns
  • This umbrella Cover the site furnace and allow bringing the chimney
  • The site is surrounded by an iron fence (sheet metal) 3 meters height from the surface of the earth in order to protect the incinerators from dust storms
  • The iron fence must have a 5 meters Width gate
  • Automatic anti-rust and heat electrical circuit must be provided
  • The furnaces are highly efficient, emissions-free, safe, and environmentally friendly and have capacity of not less than 3,000 kg of materials and the rate of burning at least 400 kg / h
  • The method of feeding the furnace through a side slot or from the top and the emission of the smoke is completely prevented.
  • a furnace Must have two rooms, one of them is the main room of not less than the “5” stoves to the process of burning materials and other secondary room of not less “2” stoves to burn resulting gas from the first process as well as the chimney
  • The main component of the body of the furnace is stainless steel box, the thickness of not less than 7 mm with a layer of zinc phosphate plated with aluminium reflector to heat
  • the thickness of the door of 150 mm and a hardness of not less than 170 kg / m 3 to be burnt, automatic comprehensive remote system.
  • Furnaces must be destructive enough to burn and incinerate the material which mentioned previously
  • furnaces must have certificates are supported global enterprises and government competent for environmental protection In the country of origin or the General Presidency of Meteorology and Environment Protection in Saudi Arabia
  • The oven can work for 24 hours so as to allow for the burning of materials for a period of not less than 12 consecutive hours and the remainder for cooling and provides full fuel tank with a capacity of 1000 L to turn on the oven.
  • Must have an automatic ignition and diesel is used
  • a furnace has the ability to withstand extreme temperatures up to “130o c And also, it guarantees continuous operation of which can be utilized for 24 hours with the ability to remove residues during the work of the oven, Insulating layer of calcium must be present in the rooms with Thickness not less than 50 mm and a wall thickness of 100 mm
  • Isolation of burning room: the space between the walls must be of the “stainless steel”. In addition, burn room must fill with Thermal insulation material.
  • Ensure that the combustion of materials emitted in the secondary room should be at least two seconds period and the room is lined with high-density ceramic fibbers
  • Incinerators must contain a system for processing (purification) gasses before emission of the smoke.
  • Incinerators must have the capacity of self-cooling after the end of the daily operating period.
  • Incinerators must have chimney not less than “4 meters” height from the surface of the oven, also, it must be thermally insulated and non-rust able, and must also be removable, installation and tide default.
  • Electrical capacity required “220/ 380-volt “60 hertz
  • Incinerators must be fitted with a control panel of the electronic keys to monitor all the necessary indicators of activation keys, as well as start-up and switch off so as to be isolated inside a metal box with the presence of the following:

Characteristics of ovens:

Alarm Sensor in the event of (crashes “burner” or purification Apparatus or heat leakage       or internal connections and Pipes )

Monitors for the temperature of the rooms

Aerosols Filter indicators/ monitors

Space temperature Detectors

Indicators for furnaces and Indicator overload

  • All equipment must be highly resistant to external conditions such as high temperature (50oc)
  • All doors must have special lock are not allowed non-persons appointed to work.
  • Providing fire extinguisher for each site with a capacity of 10 kg at least

Timer for Extinguish the Toaster automatically Determined by the Period required.


Clover's Social Media