Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste may utilize within this gear? A: This gear to medical waste, pet creature, Municipal waste, live squander. Prohibit any volatile and radiation material, liquid gas and waste waste. GB18484-2001.
Q: Treatment capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not indicate any waste material.
Clover incinerator utilize time daily to 24 hours. Between each feed/combustion time, you will find approximately 0.5-1 hours cooling time plus time for feeding squander. Actual combustion time per day is around 16 hours. The life of incinerator between 5-10 year based on utilize.
Generally, we proposition small lab, small clinic use capability under 20 kgs per hour. When incinerator use in hospital, please compute the waste output around 2kgs per people per day. If there are 200 sickbed in the hospital, that's mean you need one incinerator capability around 400kgs per day, switch to power per hour is approximately 30-40 kgs per hour. According the operation time per day, waste material, funding, development, etc, you may use capacity from 30-50 kgs per hour incinerator. *The best way to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Meeting and Testing A: We supply all files and incinerators easy to setup and operation. Customer can send people come to our factory to find out installation and operation. Generally, We do not send engineer to local site if not ask. The dispatch cost is extra based on order.
Q: Combustion Temperature A: The very first combustion chamber: 800-1000 centi degree. The next combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control manner is common control case. PLC mode based on order and model.
Q: Operation and maintenance costs A: Operation cost based on fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000USD annually maintenance according model, utilize situation.
One person can service 02 device incinerators. The staff should have fundamental electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and understand risk of medical waste to safeguard worker self with necessary protection element.
Q: The Residency period in combustion chamber A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |